    DNA extraction from mouthwash samples using Qiagen DNeasy PowersoilPro Kit

    Ahmed A Shibl, Anique Ahmad, Tsedenia Denekew, Mamon Abd AlBaqi, Aashish R Jha

    Published: 2022-10-14 DOI: 10.17504/protocols.io.eq2ly7dyrlx9/v1
    AI 解读
    浏览 1502

    Abstract

    This protocol describes how to extract DNA from mouthwash samples.

    Before start

    Set centrifuge to 4ºC

    Keep CD2 solution on ice or at 4ºC

    Prepare and label collection tubes, microcentrifuge tubes, MB spin columns, and powerbead tubes

    Steps

    1.

    Thaw the sample on ice for 0h 30m 0s

    1.1.

    Transfer the desired sample volume 1-2mL into a 1.5mL or 2mL eppendorf tube

    2.

    Centrifuge the transferred sample at maximum speed (17000x g,0h 0m 0s ) at 4°C for 0h 10m 0s

    3.

    Discard the supernatant carefully without disturbing the pellet

    3.1.

    Repeat Step 1.1 if more volume is needed to see a pellet or a higher yield of DNA is required

    4.

    Add 800µL of CD1 and vortex to resuspend pellet

    4.1.

    Spin down briefly

    5.

    Transfer entire eppendorf content in a PowerBead Pro Tube

    6.

    Secure PowerBead Pro tube onto the bead beater and run at maximum speed (17000x g,0h 0m 0s ) for 0h 5m 0s

    7.

    Centrifuge the PowerBead Pro tube at maximum speed (17000x g,0h 0m 0s ) for 0h 1m 30s

    8.

    Transfer the supernatant carefully, without disturbing the pellet, into a clean 2mL microcentrifuge tube

    9.

    Add 200µL of CD2 into the 2mL microcentrifuge tube and vortex for 0h 0m 10s

    10.

    Centrifuge the 2mL microcentrifuge tube at maximum speed (17000x g,0h 0m 0s ) for 0h 1m 30s

    11.

    Transfer the supernatant carefully without disturbing the pellet, into a clean 2mL microcentrifuge tube

    12.

    Add 600µL of CD3 into the 2 mL microcentrifuge tube and vortex for 0h 0m 10s

    13.

    Load 650µL of the lysate onto MB spin columns and centrifuge at maximum speed (17000x g,0h 0m 0s ) for 0h 1m 30s

    13.1.

    Discard flow-through and repeat step 13 to consume all the lysate

    14.

    Place the spin column onto a new collection tube, add 500µL of EA, and centrifuge at maximum speed (17000x g,0h 0m 0s ) for 0h 1m 30s

    15.

    Discard flow-through and place the spin column back into the collection tube

    16.

    Add 500µL of C5 onto the spin column and centrifuge at maximum speed (17000x g,0h 0m 0s ) for 0h 1m 30s

    17.

    Discard flow-through and place the spin column back into the collection tube

    18.

    Centrifuge at maximum speed (17000x g,0h 0m 0s ) for 0h 2m 0s and place spin column into 1.5mL eppendorf (elution) tube

    19.

    Add 50-100µL of nuclease-free water to the center of the spin column and leave at room temperature for 0h 5m 0s

    20.

    Centrifuge at maximum speed (17000x g,0h 0m 0s ) for 0h 1m 0s , quantify using Qubit, flash freeze, and store at -20/80 °C